Title: | Experimental Study on Some Properties of Recycled Polypropylene Plastics as a Partial Replacement of Coarse Aggregate in High Strength and Normal Strength Concretes |
Authors: | Marar, Khaled Hamed Alipourlashkarian, Pouria Eastern Mediterranean University, Faculty of Engineering, Dept. of Civil Engineering |
Keywords: | Civil Engineering Construction Materials--Polypropylene Polypropylene (PP) Normal strength concrete High strength concrete workability Mechanical properties Non-destructive test Water absorption Permeability Heat exposure |
Issue Date: | Sep-2019 |
Publisher: | Eastern Mediterranean University (EMU) - Doğu Akdeniz Üniversitesi (DAÜ) |
Citation: | Alipourlashkarian, Pouria. (2019). Experimental Study on Some Properties of Recycled Polypropylene Plastics as a Partial Replacement of Coarse Aggregate in High Strength and Normal Strength Concretes. Thesis (M.S.), Eastern Mediterranean University, Institute of Graduate Studies and Research, Dept. of Civil Engineering, Famagusta: North Cyprus. |
Abstract: | Previously, various studies were performed to identify safety and environmentally
friendly methods for disposing of plastics. Recently, various forms of plastics have
been incorporated in concrete to prevent direct contact of plastics with the
environment because concrete has a longer service life. In this thesis, the effects of
coarse aggregate replacement of Polypropylene as a waste material on fresh and
hardened properties of normal strength concrete (NSC) and high strength concrete
(HSC) was investigated. To do so, different percentages of polypropylene were
replaced by various volumes (0%, 10%, 20%, 30%, 40% and 50 %) of normal and
high strength concretes, with the water to cement ratio of 0.58, 0.34 for normal and
high strength concrete, respectively. In addition, Superplasticizer (Glenium 27) was
added to the NSC and HSC mixed by 0.3% and 2% cement weight, respectively.
Slump and VeBe time tests were done to analyse the physical properties of fresh
concrete. Moreover, the influences of PP replacement in the hardened concrete were
executed by performing splitting tensile strength (fs), compressive strength (fc) and
flexural strength (ff) tests. Rapid chloride permeability (RCP), heat degradation at
200 °C, water absorption, and non-destructive tests such as Ultrasonic Pulse Velocity
(Pundit) and Schmidt hammer (rebound) were also conducted.
The results showed changes in mechanical properties of normal strength concrete and
high strength concrete as the percentages of PP increases. The amount of fs, fc, and ff
of normal and high strength concrete decreased with the increase in the amount of
polypropylene at 28 days.
Furthermore, high water absorption was observed with the increasing of PP.
According to the results of the Pundit test the replacement of Polypropylene
increased the quality of concrete up to 50% in comparison with the control samples.
It is worth noting that negative effects in fc, fs, ultrasonic pulse velocity, and crack
development were observed after 200 °C heat exposure.
Keywords: Polypropylene (PP), Normal strength concrete, High strength concrete,
workability, Mechanical properties, Non-destructive test, Water absorption,
Permeability, Heat exposure ÖZ:Geçmişte plastiklerin atılmasında güvenli ve çevre dostu yöntemler belirlemek için
çeşitli çalışmalar yapılmıştı. Son zamanlarda, plastiklerin israfını ve çevreye
etkilerini azaltmak için betona çeşitli plastikler eklenmiştir.
Bu tez çalışmasında, atık agrega olarak polipropilenin iri agrega ile değişiminin,
normal mukavemetli (NMB) ve yüksek mukavemetli betonun (YMB) taze ve
sertleşmiş özelliklerine etkisi incelenmiştir. Farklı polipropilen miktarları, normal
mukavemet ve yüksek mukavemetli betona hacimsel olarak (%0, 10, 20, 30, 40 ve
50) katılmıştır ve normal mukavemetli beton için 0.58 ve yüksek mukavemetli beton
için 0.34 su-çimento oranı kullanılmıştır. Ek olarak, NMB ve YMB karışımlarına
sırasıyla %0.3 ve %2 (çimento oranında) süper akınlaştırıcı (Glenium 27)
kullanılmıştır.
Taze betonun fiziksel özelliklerini analiz etmek için slamp ve VeBe deneyleri
yapılırken, polipropilen agreglı sertleşmiş betonun mekanik özellikleri üzerindeki
etkisi, basınç dayanımı deneyi, çekme dayanımı deneyi, eğilme dayanımı deneyi,
Ultrasonik Darbe Hızı (pundit) deneyi (Pundit), Schmidt çekici deneyi, su emme
deneyi, hızlı klorür geçirgenliği deneyi ve ısı bozulması deneyi (200 °C) yapılarak
belirlenmeye çalışılmıştır.
Sonuçlara göre ise polipropilen dayanım yüzdeleri arttıkça normal dayanımlı betonun
ve yüksek dayanımlı betonun mekanik özelliklerinde değişiklikler olduğunu
göstermektedir. Basınç dayanımı, çekme dayanımı, normal ve yüksek mukavemetlı
betonun bükülme dayanımı polipropilenin artmasıyla 28 günde düşmüştür.
Polipropilen miktarı artışı ile betonda yüksek su emme gözlemlenmiştir. Pundit
deneyi, kontrol numunelerine kıyasla% 50'ye kadar polipropilen ihtiva eden
betonların beton kalitesini iyileştirdiğini göstermiştir. Basınç mukavemeti, basmada
yarma mukavemeti, ultrasonik hızı ve çatlak gelişimindeki negatif etki betonlar 200
°C ısıya maruz kaldıktan sonra gözlenmiştir.
Anahtar Kelimeler: Polipropilen (PP), Normal dayanımlı beton, Yüksek dayanımlı
beton, Işlenebilirlik, Mekanik özellikler, Tahribatsız deneyler, Su emme,
Geçirgenlik, Isıya maruz kalma |
Description: | Master of Science in Civil Engineering. Thesis (M.S.)--Eastern Mediterranean University, Faculty of Engineering, Dept. of Civil Engineering, 2019. Supervisor: Prof. Dr. Khaled Hamed Marar. |
URI: | http://hdl.handle.net/11129/5580 |
Appears in Collections: | Theses (Master's and Ph.D) – Civil Engineering
|
This item is protected by original copyright
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|