DSpace
 

EMU I-REP >
06 Sağlık Bilimleri Fakültesi (Faculty of Health Sciences) >
Tez Koleksiyonu (Master ve Doktora) – Sağlık Bilimleri / Theses (Master’s and Ph.D.) – Health Sciences >

Please use this identifier to cite or link to this item: http://hdl.handle.net/11129/6188

Title: Alt Ekstremite Protezi Kullanan Amputelerde Glittre Günlük Yaşam Aktiviteleri Testinin Geçerlilik ve Güvenilirliği
Authors: Yurt, Yasin (Tez Danışmanı)
Çiftçi, Özge
Doğu Akdeniz Üniversitesi, Sağlık Bilimleri Fakültesi, Fizyoterapi ve Rehabilitasyon Bölümü
Keywords: Fizyoterapi ve Rehabilitasyon Bölümü
Amputeler, Fiziksel aktivite, Protez
Glittre GYA, Ampute, Protez, Fiziksel Fonksiyon Testi
Issue Date: Sep-2022
Publisher: Eastern Mediterranean University (EMU) - Doğu Akdeniz Üniversitesi (DAÜ)
Citation: Çiftçi, Özge. (2022). Alt Ekstremite Protezi Kullanan Amputelerde Glittre Günlük Yaşam Aktiviteleri Testinin Geçerlilik ve Güvenilirliği. Tez (Yüksek Lisans), Doğu Akdeniz Üniversitesi, Lisansüstü Eğitim, Öğretim ve Araştırma Enstitüsü, Fizyoterapi ve Rehabilitasyon Bölümü, Gazimağusa: Kuzey Kıbrıs.
Abstract: ÖZ: Amacımız Glittre Günlük Yaşam Aktiviteleri (GYA) testinin alt ekstremite protezi kullanan amputelerde geçerliliğini ve güvenilirliğini incelemekti. Çalışmamız Doğu Akdeniz Üniversitesi Sağlık Bilimleri Fakültesi Protez Ortez ve Biyomekanik Merkezi, Kıbrıs Türk Ortopedik Özürlüler Derneği ve Tralles Ortez Protez İmalat San. Tic. Ltd.’de yürütüldü. Araştırmaya 18 yaş üstü, en az 6 aydır alt ekstremite protezi kullanan ve en az 30 metre (m) bağımsız yürüyebilen 66 birey dahil edildi. Sosyodemografik bilgiler alındıktan sonra Glittre GYA testi ardından 2 dakika yürüme testi (2DKYT), zamanlı kalk ve yürü testi (ZKYT), fonksiyonel uzanma testleri (FUT) yapıldı. Güvenilirlik için 1. ve 2. değerlendirme aynı fizyoterapist, 3. değerlendirme farklı bir fizyoterapist tarafından yapılarak değerlendirici içi ve değerlendiriciler arası uyum incelendi. 2DKYT, ZKYT ve FUT kullanılarak Glittre GYA testinin yakınsak ve ayırt edici geçerliliği incelendi. Glittre GYA testinin değerlendirici içi (r= 0,940) ve değerlendiriciler arası (r= 0,907) güvenilirliği çok yüksek bulundu (p<0,05). Ölçümlerin iç tutarlılığı ICC= 0,940 (%95 GA, 0,904-0,963) ve Cronbach’s Alpha=0,969 olarak bulundu. Glittre GYA testi 2DKYT ile negatif yönde yüksek ilişki (r= -0,808), ZKYT ile pozitif yönde yüksek ilişki (r= 0,791), FUT ile negatif yönde zayıf ilişki bulundu (r= 0,306, p<0,05). Bland Altman Grafikleri incelendiğinde Glittre GYA testinin; 2DKYT ile %97, ZKYT ile %96, FUT ile %99 uyum olduğu belirlenmiştir. Glittre GYA testinin alt ekstremite protezi kullanan bireylerde fonksiyonel kapasite değerlendirmesinde kullanılabilecek geçerli ve güvenilir bir testtir.
Our aim was to examine the validity and reliability of the Glittre Activities of Daily Living (ADL) test in amputees using a lower extremity prosthesis. Our study was conducted by the Eastern Mediterranean University Faculty of Health Sciences, Center for Prosthetics, Orthotics and Biomechanics, Cyprus Turkish Association of Orthopedic Disabled People and Tralles Ortez Protez İmalat San. Trade Ltd. was carried out. 66 individuals over the age of 18, using a lower extremity prosthesis for at least 6 months and able to walk at least 30 meters (m) independently, were included in the study. After the socio-demographic information was obtained, the Glittre ADL test followed by the 2-minute walk test (2MWT), timed get up and go test (TUG), and functional reach tests (FRT) were performed. For reliability, the 1st and 2nd evaluations were made by the same physiotherapist, and the third evaluation was made by a different physiotherapist, and the intra-rater and inter-rater compatibility was examined. The convergent and discriminative validity of the Glittre ADL test was examined using 2MWT, TUG and FRT. The intra-rater (r= 0.940) and inter-rater (r= 0.907) reliability of the Glittre ADL test was found to be very high (p<0.05). The internal consistency of the measurements was found to be ICC(Intraclass Corelation Coefficient)= 0.940 (95% CI, 0.904-0.963) and Cronbach's Alpha= 0.969. Glittre ADL test had a high negative correlation with 2MWT (r= -0.808), a high positive correlation with TUG (r= 0.791), and a weak negative correlation with FRT (r= 0.306, p<0.05). When the Bland Altman Charts were examined, the Glittre ADL test; It was determined that the agreement with 2MWT was 97%, with TUG 96%, and 99% with FRT. Glittre ADL test is a valid and reliable test for assessing functional capacity in individuals using lower extremity prostheses.
Description: Fizyoterapi ve Rehabilitasyon - Yüksek Lisans Tezi. Lisansüstü Eğitim, Öğretim ve Araştırma Enstitüsü. Tez (Yüksek Lisans) - Doğu Akdeniz Üniversitesi, Sağlık Bilimleri Fakültesi, Fizyoterapi ve Rehabilitasyon Bölümü, 2022. Tez Danışmanı: Doç. Dr. Yasin Yurt
URI: http://hdl.handle.net/11129/6188
Appears in Collections:Tez Koleksiyonu (Master ve Doktora) – Sağlık Bilimleri / Theses (Master’s and Ph.D.) – Health Sciences

Files in This Item:

File Description SizeFormat
Ciftciozge.pdfTez, Master1.33 MBAdobe PDFView/Open


This item is protected by original copyright

Recommend this item
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback