Single and double pass solar air heaters with wire mesh as packing bed

EMU I-REP

Show simple item record

dc.contributor.author Aldabbagh, LBY
dc.contributor.author Egelioğlu, Fuat
dc.contributor.author İlkan, Mustafa
dc.date.accessioned 2016-03-07T11:24:51Z
dc.date.available 2016-03-07T11:24:51Z
dc.date.issued 2010-09
dc.identifier.issn 0360-5442 (online)
dc.identifier.uri http://dx.doi.org/10.1016/j.energy.2010.05.028
dc.identifier.uri http://hdl.handle.net/11129/2205
dc.description Due to copyright restrictions, the access to the publisher version (published version) of this article is only available via subscription. You may click URI (with DOI: 10.1016/j.energy.2010.05.028) and have access to the Publisher Version of this article through the publisher web site or online databases, if your Library or institution has subscription to the related journal or publication. en_US
dc.description.abstract The thermal performances of single and double pass solar air heaters with steel wire mesh layers are used instead of a flat absorber plate are investigated experimentally. The effects of mass flow rate of air on the outlet temperature and thermal efficiency were studied. The results indicate that the efficiency increases with increasing the mass flow rate for the range of the flow rate used in this work between 0.012 and 0.038 kg/s. For the same flow rate, the efficiency of the double pass is found to be higher than the single pass by 34–45%. Moreover, the maximum efficiencies obtained for the single and the double pass air collectors are 45.93 and 83.65% respectively for the mass flow rate of 0.038 kg/s. Comparison of the results of a packed bed collector with those of a conventional collector shows a substantial enhancement in the thermal efficiency. en_US
dc.language.iso eng en_US
dc.publisher Pergamon en_US
dc.relation.isversionof 10.1016/j.energy.2010.05.028 en_US
dc.rights info:eu-repo/semantics/restrictedAccess en_US
dc.subject Solar air heater en_US
dc.subject Thermal efficiency en_US
dc.subject Single and double pass solar air heater en_US
dc.title Single and double pass solar air heaters with wire mesh as packing bed en_US
dc.type article en_US
dc.relation.journal Single and double pass solar air heaters with wire mesh as packing bed en_US
dc.contributor.department School of Computing And Technology en_US
dc.identifier.volume 35 en_US
dc.identifier.issue 9 en_US
dc.identifier.startpage 3783 en_US
dc.identifier.endpage 3787 en_US