dc.description.abstractThe radon exhalation rates and radon concentrations in granite stones used in Iran were measured by means of a high-resolution high purity Germanium gamma-spectroscopy system (passive method) and an AlphaGUARD model PQ 2000 (active method). For standard rooms (4.0 5.0 m area2.8 height) where ground and walls have been covered by granite stones, the radon concentration and the radon exhalation rate by two methods were calculated. The activity concentrations of Ra-226 in the selected granite samples ranged from 3.8 to 94.2 Bq kg(1). The radon exhalation rate from the calculation of the Ra-226 activity concentration was obtained. The radon exhalation rates were 1.317.86 Bq m(2)h(1). The direction measurements using an AlphaGUARD were from 218 to 1306 Bq m(3) with a mean of 625 Bq m(3). Also, the exhalation rates measured by the passive and active methods were compared and the results of this study were the same, with the active method being 22 higher than the passive method.
dc.description.sponsorshipScience and Technology Research Institute of Iran
dc.description.sponsorshipThe financial support was provided by Science and Technology Research Institute of Iran.
dc.identifier.doi10.1093/rpd/nct163
dc.identifier.endpage574
dc.identifier.issn0144-8420
dc.identifier.issn1742-3406
dc.identifier.issue4
dc.identifier.orcid0000-0002-4664-3744
dc.identifier.pmid23798709
dc.identifier.scopus2-s2.0-84890043265
dc.identifier.scopusqualityQ3
dc.identifier.startpage570
dc.identifier.urihttps://doi.org/10.1093/rpd/nct163
dc.identifier.urihttps://hdl.handle.net/11129/14653
dc.identifier.volume157
dc.identifier.wosWOS:000328376600012
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherOxford Univ Press
dc.relation.ispartofRadiation Protection Dosimetry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260204
dc.subjectNatural Radioactivity
dc.subjectHazards
dc.subjectIran
dc.titleComparison of active and passive methods for radon exhalation from a high-exposure building material