Experimental study of the potential of eucalyptus fibres for evaporative cooling

dc.contributor.authorDogramaci, Pervin Abohorlu
dc.contributor.authorRiffat, Saffa
dc.contributor.authorGan, Guohui
dc.contributor.authorAydin, Devrim
dc.date.accessioned2026-02-06T18:40:27Z
dc.date.issued2019
dc.departmentDoğu Akdeniz Üniversitesi
dc.description.abstractEnergy consumption by human enhanced activities has led to distinctive environmental problems; in particular, climate change and global warming. In hot regions, the main reason for energy consumption comes from the cooling of many buildings. The intensity and duration of the sunshine in hot regions have a direct relation with the usage of cooling systems. The aim of this paper is to study the performance of eucalyptus fibre pads which can be used as a new material for the evaporative cooling process in order to reduce the energy consumption caused by cooling loads. A wind tunnel is used to investigate the performance of evaporative cooling by eucalyptus fibres. This paper also analyses the behaviour of the eucalyptus fibres under different conditions. From the measurement of one material sample, it was found that the maximum reduction of air temperature was between 11.3 degrees C and 6.6 degrees C, while the maximum cooling efficiency was in the range of 71% and 49% at 0.1 and 0.6 m/s air velocities respectively. Corresponding cooling capacities were also calculated as 108 W and 409 W indicating a directly proportional relation between air velocity and cooling performance. (C) 2018 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.renene.2018.07.005
dc.identifier.endpage260
dc.identifier.issn0960-1481
dc.identifier.orcid0000-0002-5292-7567
dc.identifier.orcid0000-0001-8831-5784
dc.identifier.orcid0000-0002-4457-3586
dc.identifier.scopus2-s2.0-85050002451
dc.identifier.scopusqualityQ1
dc.identifier.startpage250
dc.identifier.urihttps://doi.org/10.1016/j.renene.2018.07.005
dc.identifier.urihttps://hdl.handle.net/11129/13327
dc.identifier.volume131
dc.identifier.wosWOS:000449892600025
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofRenewable Energy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260204
dc.subjectEvaporative cooling
dc.subjectCooling efficiency
dc.subjectEucalyptus fibres
dc.subjectWind tunnel
dc.titleExperimental study of the potential of eucalyptus fibres for evaporative cooling
dc.typeArticle

Files