Lyapunov Energy Function Based Control Method for Three-Phase UPS Inverters With Output Voltage Feedback Loops

dc.contributor.authorBayhan, Sertac
dc.contributor.authorSeyedalipour, S. Sajjad
dc.contributor.authorKomurcugil, Hasan
dc.contributor.authorAbu-Rub, Haitham
dc.date.accessioned2026-02-06T18:49:38Z
dc.date.issued2019
dc.departmentDoğu Akdeniz Üniversitesi
dc.description.abstractIn this study, a Lyapunov energy function based control method with output voltage feedback loops is proposed for three-phase uninterruptible power supply (UPS) inverters. The presented paper demonstrates that the traditional Lyapunov-energy-function-based control method not only leads to considerable steady-state error in the output voltage, but also distorts the output voltage waveforms. Therefore, a modification has been performed on the traditional Lyapunov-energy-function-based control by incorporating the output voltage feedback loops in the control variables. The robustness of the proposed control method has been studied analytically through transfer functions which are expressed as the ratio of the output voltage to its reference. These analytical results are validated experimentally. In addition, the steady-state and dynamic performances of the proposed control method are also tested experimentally on a three-phase UPS inverter operating with linear (resistive) and nonlinear (diode-bridge rectifier) loads. As a consequence of incorporating output voltage feedback loops into the control variables, the proposed control method offers strong robustness against variations in LC filter parameters, high-quality sinusoidal output voltage along with acceptable total harmonic distortion (THD) values under linear and nonlinear loads, fast dynamic response under abrupt load changes, and negligibly small steady-state error in the output voltage.
dc.description.sponsorshipQatar National Library
dc.description.sponsorshipThis work was supported by the Qatar National Library.
dc.identifier.doi10.1109/ACCESS.2019.2934404
dc.identifier.endpage113711
dc.identifier.issn2169-3536
dc.identifier.orcid0000-0003-4728-6416
dc.identifier.orcid0000-0001-8687-3942
dc.identifier.orcid0000-0003-2027-532X
dc.identifier.scopus2-s2.0-85078698298
dc.identifier.scopusqualityQ1
dc.identifier.startpage113699
dc.identifier.urihttps://doi.org/10.1109/ACCESS.2019.2934404
dc.identifier.urihttps://hdl.handle.net/11129/14967
dc.identifier.volume7
dc.identifier.wosWOS:000560549300057
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherIEEE-Inst Electrical Electronics Engineers Inc
dc.relation.ispartofIeee Access
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260204
dc.subjectVoltage control
dc.subjectUninterruptible power systems
dc.subjectInverters
dc.subjectSteady-state
dc.subjectRobustness
dc.subjectFeedback loop
dc.subjectActive filters
dc.subjectUninterruptible power supply inverter
dc.subjectLyapunov energy function
dc.subjectoutput voltage feedback
dc.subjectsteady-state error
dc.subjectrobustness
dc.titleLyapunov Energy Function Based Control Method for Three-Phase UPS Inverters With Output Voltage Feedback Loops