Experimental Study of the Slit Spacing and Bed Height on the Thermal Performance of Slit-Glazed Solar Air Heater

dc.contributor.authorMousavi, Seyyed Mahdi Taheri
dc.contributor.authorEgelioglu, Fuat
dc.date.accessioned2026-02-06T18:52:33Z
dc.date.issued2017
dc.departmentDoğu Akdeniz Üniversitesi
dc.description.abstractThe thermal performances of three slit-glazed solar air heaters (SGSAHs) were investigated experimentally. Three SGSAHs with different bed heights (7 cm, 5 cm, and 3 cm) were fabricated with multiple glass panes used for glazing. The length, width, and thickness of each pane were 154 cm, 6 cm, and 0.4 cm, respectively. Ambient air was continuously withdrawn through the gaps between the glass panes by fans. The experiments were conducted for four different gap distances between the glass panes (0.5 mm, 1 mm, 2 mm, and 3 mm) and the air mass flow rate was varied between 0.014 kg/s and 0.057 kg/s. The effects of air mass flux on the outlet temperature and thermal efficiency were studied. For the SGSAH with bed height of 7 cm and glass pane gap distance of 0.5 mm, the highest efficiency was obtained as 82% at a mass flow rate of 0.057 kg/s and the air temperature difference between the inlet and the outlet (Delta T) was maximum (27 degrees C) when the mass flow rate was least. The results demonstrate that for lower mass flow rates and larger gaps, the performance of SGSAH with a bed height of 3 cm was better compared to that of others. However, for higher mass flow rates, the SGSAH with 7 cm bed height performed better.
dc.identifier.doi10.1155/2017/9851376
dc.identifier.issn1110-662X
dc.identifier.issn1687-529X
dc.identifier.orcid0000-0003-1624-0757
dc.identifier.scopus2-s2.0-85031316083
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1155/2017/9851376
dc.identifier.urihttps://hdl.handle.net/11129/15556
dc.identifier.volume2017
dc.identifier.wosWOS:000407788400001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherHindawi Ltd
dc.relation.ispartofInternational Journal of Photoenergy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260204
dc.subjectThermohydraulic Performance
dc.subjectFlow Distribution
dc.subjectWire Mesh
dc.subjectCollector
dc.subjectFins
dc.subjectEfficiency
dc.subjectDesign
dc.subjectSingle
dc.subjectEnergy
dc.titleExperimental Study of the Slit Spacing and Bed Height on the Thermal Performance of Slit-Glazed Solar Air Heater
dc.typeArticle

Files