Experimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors

dc.contributor.authorMousavi, Seyed Mahdi Taheri
dc.contributor.authorEgelioglu, Fuat
dc.date.accessioned2026-02-06T18:52:51Z
dc.date.issued2017
dc.departmentDoğu Akdeniz Üniversitesi
dc.description.abstractAn experimental study on the thermal performance of slit-glazed collectors was conducted. Here, glass panes were used as slit glazing cover, and the air was blown continuously through the gaps between them by fan (slit glazing is an uncomplicated and economical process compared to glass perforation). In this study, the effect of the width of glass panes, the distance between the slits, and mass flow rates were studied on three slit-glazed collectors. A glass pane with the length of 131 cm and thickness 0.4 cm was studied for three different slit widths: 6, 5, and 4 cm. The experiments are conducted with four different gap distances between the glass panes (0.5, 1, 2, and 3 mm) and three air mass flow rates (0.014, 0.022, and 0.029 kg/s). The experimental results indicated that the maximum thermal efficiency of 75% was obtained when the gap distance was 0.5 mm, slit width was 4 cm, and the mass flow rate was 0.029 kg/s. The maximum rise in air temperature was noted as 28 degrees C when the gap distance and slit widths were 0.5 mm and 5 cm, respectively. Hence, the best thermal performance was achieved with the smallest slit width and gap distance parameter values.
dc.identifier.doi10.1177/1687814017728477
dc.identifier.issn1687-8140
dc.identifier.issue9
dc.identifier.orcid0000-0003-1624-0757
dc.identifier.scopus2-s2.0-85030238055
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1177/1687814017728477
dc.identifier.urihttps://hdl.handle.net/11129/15722
dc.identifier.volume9
dc.identifier.wosWOS:000410811200001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherSage Publications Ltd
dc.relation.ispartofAdvances in Mechanical Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260204
dc.subjectGlazed slit
dc.subjecttemperature rise
dc.subjectthermal efficiency
dc.subjectgap distance
dc.subjectslit width
dc.subjectmass flow rate
dc.titleExperimental study of the effect of slit width and slit spacing on the thermal performance of slit-glazed collectors
dc.typeArticle

Files