Thermal Comfort and Energy Performance of Atrium in Mediterranean Climate
| dc.contributor.author | Aram, Reihaneh | |
| dc.contributor.author | Alibaba, Halil Zafer | |
| dc.date.accessioned | 2026-02-06T18:24:18Z | |
| dc.date.issued | 2019 | |
| dc.department | Doğu Akdeniz Üniversitesi | |
| dc.description.abstract | This paper aims to determine the optimal single-story office building model with a corner atrium regarding different atrium orientations and office-building window-opening ratios in the Mediterranean climate via EDSL Tas software. When window-opening ratios were 25% and 50% at the northeast and southeast orientations of atriums and office spaces, thermal comfort was achieved according to categories B and C, respectively, within the cold season. Additionally, for the northeast atrium orientation with 25%, 137.2 W and 189.5 W of heat loss and gain in the office zone, and 37.7 W and 204.7 W of heat loss and gain in the atrium zone were recorded. Moreover, for the northeast atrium orientation with 50%, 134.5 W and 134.2 W of heat loss and gain in the office zone, and 40 W and 192 W of heat loss and gain in the atrium zone were recorded. On the other hand, for the southeast atrium orientation with 25%, 108.7 W and 143 W of heat loss and gain in the office zone, and 68.8 W and 130 W of heat loss and gain in the atrium zone were recorded, while, with 50%, 111.7 W and 142.7 W of heat loss and gain in the office zone, and 67.5 W and 121.2 W of heat loss and gain in the atrium zone were recorded. In the warm season, the atrium and office spaces were not thermally comfortable. | |
| dc.identifier.doi | 10.3390/su11041213 | |
| dc.identifier.issn | 2071-1050 | |
| dc.identifier.issue | 4 | |
| dc.identifier.orcid | 0000-0002-1394-599X | |
| dc.identifier.scopus | 2-s2.0-85065923017 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.uri | https://doi.org/10.3390/su11041213 | |
| dc.identifier.uri | https://hdl.handle.net/11129/10144 | |
| dc.identifier.volume | 11 | |
| dc.identifier.wos | WOS:000460819100273 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Mdpi | |
| dc.relation.ispartof | Sustainability | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WoS_20260204 | |
| dc.subject | thermal comfort | |
| dc.subject | energy performance | |
| dc.subject | atrium | |
| dc.subject | EDSL Tas | |
| dc.subject | predicted mean vote (PMV) | |
| dc.subject | predicted percentage of dissatisfied (PPD) | |
| dc.title | Thermal Comfort and Energy Performance of Atrium in Mediterranean Climate | |
| dc.type | Article |