Biomechanical analysis of normal, injured and implanted shoulder joint

dc.contributor.authorAzizi, Aydin
dc.contributor.authorAshkzari, Ali
dc.date.accessioned2026-02-06T17:59:14Z
dc.date.issued2014
dc.departmentDoğu Akdeniz Üniversitesi
dc.description2nd International Conference on Materials, Transportation and Environmental Engineering, CMTEE 2014 -- 2014-07-30 through 2014-07-31 -- Kunming -- 114820
dc.description.abstractThe biomechanics of the glenohumeral joint depend on the interaction of both static and dynamic stabilizing structures. The combined effect of these stabilizers is to support the multiple degrees of motion within the glenohumeral joint. Total shoulder arthroplasty requires release of contracted tissues, repair of rotator cuff defects, reconstruction of normal skeletal anatomy with proper sizing, and positioning of components. Arthroplasty of the shoulder is unlike arthroplasty of the hinge joints when the collateral ligaments afford a high degree of stability and is even distinct from the hip when bony conformity is large and range of motion is less. The goal of this paper is biomechanical analyses of normal, injured and implanted shoulder joint. © (2014) Trans Tech Publications, Switzerland.
dc.description.sponsorshipChienKuo Technology University; International Frontiers of science and technology Research Association; National Cheng Kung University; National Chi Nan University; National Chin-Yi University of Technology; National Sun Yan-Sen University; Trans Tech Publications
dc.identifier.doi10.4028/www.scientific.net/AMR.1030-1032.2309
dc.identifier.endpage2312
dc.identifier.isbn9783037858257
dc.identifier.isbn9783037853566
dc.identifier.isbn9783037855942
dc.identifier.isbn9780878499724
dc.identifier.isbn9783037851234
dc.identifier.isbn9783037856383
dc.identifier.isbn9783037855225
dc.identifier.isbn9780878494033
dc.identifier.isbn9783037851258
dc.identifier.isbn9783038351504
dc.identifier.issn1022-6680
dc.identifier.scopus2-s2.0-84913556246
dc.identifier.scopusqualityN/A
dc.identifier.startpage2309
dc.identifier.urihttps://doi.org/10.4028/www.scientific.net/AMR.1030-1032.2309
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/
dc.identifier.urihttps://hdl.handle.net/11129/7957
dc.identifier.volume1030-1032
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTrans Tech Publications Ltd ttp@transtec.ch
dc.relation.ispartofAdvanced Materials Research
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_Scopus_20260204
dc.subjectArthroplasty
dc.subjectBiomechanical analyses
dc.subjectGlenohumeral joint
dc.subjectShoulder joint
dc.titleBiomechanical analysis of normal, injured and implanted shoulder joint
dc.typeConference Object

Files