Single and double pass solar air heaters with partially perforated cover and packed mesh

dc.contributor.authorNowzari, Raheleh
dc.contributor.authorAldabbagh, L. B. Y.
dc.contributor.authorEgelioglu, F.
dc.date.accessioned2026-02-06T18:37:56Z
dc.date.issued2014
dc.departmentDoğu Akdeniz Üniversitesi
dc.description.abstractIn this study, the thermal performance of the single and double pass solar air heaters with normal glazing and with quarter perforated cover was investigated experimentally. The solar air collector was tested with two different perforated covers in which the holes made on one cover had the center-to-center distance of 20D (6 cm) and on the other cover it was 10D (3 cm), where D (0.3 cm) was the hole diameter. The air mass flow rate was varied between 0.011 kg/s and 0.037 kg/s. The efficiency of the double pass was always greater than the single pass air heater by 5-22.7% for the same air mass flow rate. At mass flow rate of 0.037 kg/s, the average efficiency of single and double pass air heaters with normal glazing were 49.98% and 53.67%, respectively. It was found that, the efficiency of the air heater with 10D perforated cover is slightly higher than the one with 20D perforated cover for both single and counter flow collectors. The average efficiency of single and double pass solar air heaters with 10D perforated cover were 46.40% and 54.76%, respectively, at mass flow rate of 0.032 kg/s while at the same mass flow rate, the average efficiency of single and double pass air heaters with normal glazing were 49.36% and 51.70%, respectively. (C) 2014 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.energy.2014.06.069
dc.identifier.endpage702
dc.identifier.issn0360-5442
dc.identifier.issn1873-6785
dc.identifier.orcid0000-0001-6601-4235
dc.identifier.orcid0000-0003-1130-5224
dc.identifier.scopus2-s2.0-84905731523
dc.identifier.scopusqualityQ1
dc.identifier.startpage694
dc.identifier.urihttps://doi.org/10.1016/j.energy.2014.06.069
dc.identifier.urihttps://hdl.handle.net/11129/12692
dc.identifier.volume73
dc.identifier.wosWOS:000341334200060
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofEnergy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260204
dc.subjectSolar air heater
dc.subjectPerforated cover
dc.subjectPacked bed
dc.subjectThermal efficiency
dc.titleSingle and double pass solar air heaters with partially perforated cover and packed mesh
dc.typeArticle

Files