Building's Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core
| dc.contributor.author | Jouneghani, Kourosh T. A. L. E. B., I | |
| dc.contributor.author | Hosseini, Mahmood | |
| dc.contributor.author | Rohanimanesh, Mohammad Sadegh | |
| dc.contributor.author | Raissi, Morteza | |
| dc.date.accessioned | 2026-02-06T18:26:43Z | |
| dc.date.issued | 2023 | |
| dc.department | Doğu Akdeniz Üniversitesi | |
| dc.description.abstract | The fundamental period of the seismically isolated buildings may be close to that of the long period pulses of near-field earthquakes, leading to very large lateral displacements in isolators, which in turn can considerably reduce the stability of isolators, increase the chance of collision of the isolated buildings to adjacent buildings, or even result in overturning of the isolated buildings. Therefore, it is important to control these types of buildings , reduce the amount of lateral displacement in their isolating system. In this study, by conducting a series of time history analyses for a set of five multi-story steel buildings with various numbers of stories from 3 to 14. Each building is considered to have a very stiff core structure and a set of crosswise viscous dampers, connecting the building structure to the core structure at the lowest and the top floors, as well as the same structures without the core structure and dampers. The effect of stiff core and dampers in reducing the lateral displacement at isolators has been shown. Results indicate that by the proposed technique, the lateral displacement of the base isolation system is significantly decreased particularly for low-rise buildings. | |
| dc.identifier.doi | 10.18400/tjce/1265467 | |
| dc.identifier.endpage | 42 | |
| dc.identifier.issn | 2822-6836 | |
| dc.identifier.issue | 3 | |
| dc.identifier.orcid | 0000-0003-3142-4087 | |
| dc.identifier.orcid | 0000-0003-4340-0381 | |
| dc.identifier.orcid | 0000-0003-2364-1268 | |
| dc.identifier.scopus | 2-s2.0-85161067008 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 1 | |
| dc.identifier.trdizinid | 1281072 | |
| dc.identifier.uri | https://doi.org/10.18400/tjce/1265467 | |
| dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/1281072 | |
| dc.identifier.uri | https://hdl.handle.net/11129/10613 | |
| dc.identifier.volume | 34 | |
| dc.identifier.wos | WOS:000993413100001 | |
| dc.identifier.wosquality | Q4 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | TR-Dizin | |
| dc.language.iso | en | |
| dc.publisher | Turkish Chamber Civil Engineers | |
| dc.relation.ispartof | Turkish Journal of Civil Engineering | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260204 | |
| dc.subject | Control of displacement | |
| dc.subject | base-isolated structures | |
| dc.subject | crosswise dissipators | |
| dc.subject | central rigid support | |
| dc.title | Building's Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core | |
| dc.type | Article |