Building's Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core

dc.contributor.authorJouneghani, Kourosh T. A. L. E. B., I
dc.contributor.authorHosseini, Mahmood
dc.contributor.authorRohanimanesh, Mohammad Sadegh
dc.contributor.authorRaissi, Morteza
dc.date.accessioned2026-02-06T18:26:43Z
dc.date.issued2023
dc.departmentDoğu Akdeniz Üniversitesi
dc.description.abstractThe fundamental period of the seismically isolated buildings may be close to that of the long period pulses of near-field earthquakes, leading to very large lateral displacements in isolators, which in turn can considerably reduce the stability of isolators, increase the chance of collision of the isolated buildings to adjacent buildings, or even result in overturning of the isolated buildings. Therefore, it is important to control these types of buildings , reduce the amount of lateral displacement in their isolating system. In this study, by conducting a series of time history analyses for a set of five multi-story steel buildings with various numbers of stories from 3 to 14. Each building is considered to have a very stiff core structure and a set of crosswise viscous dampers, connecting the building structure to the core structure at the lowest and the top floors, as well as the same structures without the core structure and dampers. The effect of stiff core and dampers in reducing the lateral displacement at isolators has been shown. Results indicate that by the proposed technique, the lateral displacement of the base isolation system is significantly decreased particularly for low-rise buildings.
dc.identifier.doi10.18400/tjce/1265467
dc.identifier.endpage42
dc.identifier.issn2822-6836
dc.identifier.issue3
dc.identifier.orcid0000-0003-3142-4087
dc.identifier.orcid0000-0003-4340-0381
dc.identifier.orcid0000-0003-2364-1268
dc.identifier.scopus2-s2.0-85161067008
dc.identifier.scopusqualityQ3
dc.identifier.startpage1
dc.identifier.trdizinid1281072
dc.identifier.urihttps://doi.org/10.18400/tjce/1265467
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1281072
dc.identifier.urihttps://hdl.handle.net/11129/10613
dc.identifier.volume34
dc.identifier.wosWOS:000993413100001
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherTurkish Chamber Civil Engineers
dc.relation.ispartofTurkish Journal of Civil Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260204
dc.subjectControl of displacement
dc.subjectbase-isolated structures
dc.subjectcrosswise dissipators
dc.subjectcentral rigid support
dc.titleBuilding's Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core
dc.typeArticle

Files