Transient Performance Analysis of a Model Building Integrated with a Trombe-Wall

dc.contributor.authorNowzari, Raheleh
dc.contributor.authorAtikol, U.
dc.date.accessioned2026-02-06T18:28:25Z
dc.date.issued2009
dc.departmentDoğu Akdeniz Üniversitesi
dc.description7th IASME/WSEAS International Conference on Heat Transfer, Thermal Engineering and Environment (HTE '09) -- AUG 20-22, 2009 -- Moscow, RUSSIA
dc.description.abstractThe objective of this study is to investigate the temperature behavior of a hypothetical two-story building with a total floor area of 120 m(2) by modeling and simulation with TRNSYS (Transient System Simulation) program. A vented Trombe wall is used on the South facade of the ground floor. Additionally a direct gain window of area 6.5 m(2) is placed on the south facade of the First floor. The hourly indoor temperature variations on the ground floor are determined. It is assumed that the model building is located in Larnaca, Cyprus. The results of the simulation show that approximately 95% of the total heating demand of the 60m(2)-zone can be met by a vented Trombe wall of area 15m(2). It is verified that thermally Insulating the building with 5cm-thick extruded polystyrene improves the thermal comfort by approximately 17%. It is observed that with a Trombe wall of area 15m(2) the room air temperature can be easily maintained in the range between 19 and 21.5 degrees C, whereas the temperature on the First floor fluctuates between 17.3 and 20.5 degrees C during the coldest days of winter while the outside temperature ranges between 4 and 14 degrees C. The Life Cycle Cost (LCC) analysis indicates that constructing a 15m(2) Thermal storage wall in Cyprus is economically feasible compared to installing a 3-kW gas heater, as the saving-to-Investment ratio is found to be 2.3.
dc.description.sponsorshipIASME,WSEAS
dc.identifier.endpage62
dc.identifier.isbn978-960-474-105-2
dc.identifier.orcid0000-0001-6601-4235
dc.identifier.scopusqualityN/A
dc.identifier.startpage57
dc.identifier.urihttps://hdl.handle.net/11129/10928
dc.identifier.wosWOS:000274284200008
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherWorld Scientific And Engineering Acad And Soc
dc.relation.ispartofProceedings of the 7Th Iasme/Wseas International Conference on Heat Transfer, Thermal Engineering and Environment (Hte'09)
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260204
dc.subjectPassive building
dc.subjectThermal storage wall
dc.subjectTrombe wall
dc.subjectTRNSYS
dc.subjectIndirect solar heating system
dc.titleTransient Performance Analysis of a Model Building Integrated with a Trombe-Wall
dc.typeConference Object

Files